Specifications

        

FOUNDATION:         675 x 225 concrete strip laid over 50 mm thick blinding at a depth of 900 mm below the ground level.

FLOORS:                   Earth filling.

WALLS:                     All walls are 225 sandcrete hollow blocks with 25 mortar rendering.

DOORS:                     D1 – 1200 x 2100 x 40 mm panel wooden door with 100 x 50 mm hardwood timber frame.
                                               
                                    D2 – 900 x 2100 x 400 mm flush wooden door with
100 x 50 mm hardwood timber frame.

                                    D3 – 750 x 2100 x 400 mm flush wooden door with
100 x 50 mm hardwood timber frame.

WINDOWS:               All windows are glazed aluminium sliding type with
100 x 50 mm aluminium frames.

W1 – 1800 x 1200                 (2-bays).
W2 –  1200 x 1200                (2-bays).
W3 – 1800 x 600                   (2-bays).
W4 – 600 x 600                     (1-bay).
BEAMS, COLUMNS
AND LINTELS:                     225 x 225 reinforced concrete.

THRESHOLD STEPS:                      Tread              -           300
                                                            Rise                -           150

VERANDAH:             Metal balustrades (MB) 900 mm high measured from floor level.

ROOF:                        Double pitched timber roof with corrugated aluminium roofing sheets.
                                    Eaves projection       –          600 mm.
                                    Pitch                            -           30º
                                    Height from ground floor to ceiling – 3000.