Question 8

(a) State the steps required when using a multimeter to measure a direct current.

(b) A galvanometer having full scale deflection of 10mA is to be used to measure a current of 10A. Calculate the value of the shunt resistor.

_____________________________________________________________________________________________________
OBSERVATION

The excepted   
(a) When a multi-meter is to be used, the measurement of d.c current or voltage, the following  are the steps to be taken:
      -              the meter knob is switched to the “DC” section.
    -              A measurement range with value equal to or greater than the maximum value of voltage or                       current to be measured is selected.
     -              Multimeter is then connected (in series for current measurement or parallel for voltage                               measurement) to terminals from which measurements are to be taken.
     -              Care must be taken to ensure that the meter’s real lead is connected to the positive terminal                  and the black lead to the negative terminal.        
                                                        x
  (b) With reference to the equivalent circuit displayed above, it is clear that
                                ISRS = ImRm
                                Since IS = 10 – 0.01 = 9.99A; and Im = 0.01A
                                It follows that 9.99Rs = 0.01Rm
                                Therefore RS = (0.01/9.99) Rm
The question was on measuring instruments and very few candidates attempted it. In part (a), the                 candidates’ responses were scantly coherent.
In part(b), a few candidate wisely avoided the question which could be attributed to the value of the                 galvanometer’s internal resistance which was not stated.

 