Most candidates were able to:
- show the recessed portion of the building, both on the wall and at the roof;
- distinguish the floor level from the ground level;
- represent correctly, the position of the threshold steps.
However, most of the candidates failed to:
- draw the reinforced concrete flat roof;
- draw the specified window and door type;
- show the balustrade at the veranda;
- provide door frames for the doors.
The respective front and side elevations of the building is as shown on the next page.