SPECIFICATIONS

FOUNDATION:        675 x 225 concrete strip laid over 50 thick blinding at a depth of 900 below the ground level.

FLOORS:               300 hardcore.
                           150 concrete slab.
                           25 mortar screed.

WALLS:                All walls are 225 sandcrete hollow blocks.

BEAMS/LINTELS:    225 x 225 reinforced concrete.

CAPPING COURSE: 225 x 150

DOORS:                DW – Panel combined with window (3-bay) 1220 x 2100 x 40;
                           Window 2700 x 1200 with 100 x 50 hardwod timber frame.
                                   
                           D1 -    Panel wooden 1200 x 2100 x 40 with 100 x 50 hardwood
                           timber frame.

                           D2 -   Flush wooden 900 x 2100 x 40 with 100 x 50 hardwood
                           timber frame.

                           D3  -     Flush wooden 750 x 2100 x 40 with 100 x 50 hardwood
                           timber frame.

WINDOWS:               All windows are ‘NACCO’ louver type with 100 x 50 timber frames.        
                                    W1 -  1800 x 1200  (2-bay).
                                    W2 -  1500 x 1200  (2-bay).
                                    W3 -  900 x 1200    (1-bay).
                                    W4 -  600 x 600      (1-bay).

ROOF:    Timber -       Double pitched with corrugated aluminium sheet.
                                    Pitch  - 30o.
                                    Eaves projection  -  600
                                    Height from ground floor to ceiling  -  2700.
                                    Reinforced concrete – (over corridor, kitchen, pantry,
Bedroom 2, Bath and WC)
Eaves projection  -  600
Thickness  -  150
Height from ground floor to soffit – 2250.

            VERANDAH:                    Metal balustrade (MB) 900 high measured from floor level.

            THRESHOLD STEPS:          Rise     -           150
                                                Tread   -           300