Draw to a scale of 1:50, the detailed section A - A of the building from foundation to the roof.
Most candidates were able to:
- locate the doors and windows correctly;
- show the correct graphical representation of windows in section;
- use sectional drawing to illustrate the assemblage of the roof structure's timber
members.
However, some of them failed to:
- lay the strip foundation at the depth specified;
- draw the required building section to scale;
- draw the semi-circular arches;
- dimension and label the spaces between the floor and ceiling;
- show the wardrobe in elevation.
The detailed section A -A of the building from foundation to the roof is as shown on the next
page.