It was observed that many of the  candidates were unable to:
                        
                          - draw  to scale;
- dimension  their drawings;
- prepare  the doors and windows schedules.
 
                        To overcome these weaknesses,  candidates should be:
                        -           well  grounded in the rudiments of technical drawing;
                          -           given  ample drawing assignments;
                          -           well  acquainted with scales used in the production of building drawings.
                         
                         
                         
                         
                        4.         DETAILED COMMENTS ON EACH QUESTION
                                                                                      SPECIFICATIONS
                        FOUNDATION:                      675  x 225 concrete strip laid at a depth of 900 below ground level.
                                    FLOORS:                               Earth filling.
                                                               Hardcore 300 .
                                                              Concrete  slab 150;.
                                                              Mortar  screed.25 
                        WALLS:                                  All  walls are 225 sandcrete hollow blocks with 12 mortar rendering on both sides.
              
                          DOORS:                                 D1 –  1200 x 2100 glazed metal door;
                          D2  - 900 x 2100   2-panel  wooden door with 100 x 75  hardwood timber frame.
                          D3  – 750 x 2100 Flush wooden with 100 x 75 hardwood timber frame.
                        WINDOWS:                            All windows are glazed  aluminium sliding type:
                          W1 – 1800 x 1200     (3  – bays);
                                                              W2  – 1200 x 1200    (2 – bays);
                                                              W3   –    900 x 1200                (2 – bays)
                                                  W4    –    600  x  600   (2  – bays).
                        ARCH:                                    Semi-circular type.
                                                                        Span   –          2400
                                                  Height –          2400
                        BEAMS/LINTELS:                 225 x 225 reinforced concrete.
                                      
                          COLUMNS:                            225 x 225 reinforced  concrete.
                        WARDROBES:                      Partitioned into cloth and  box compartments.
                          600 x 2100  x 3000 with sliding flush wooden doors in 50 x 75 hardwood timber frame.
                        THRESHOLD  STEPS:          Tread  –  300
                                                  Riser    –    150
                                                              
                          ROOF:                                    Double  pitched timber roof with galvanized iron roofing sheets.
                                                              Eaves  projection – 750.
                                                              Pitch  – 15º.
                                                              Height  from finished ground floor to ceiling – 3000.