                        | Question 1
 |  
                        | Question  1 
                            (a)      Draw a thermosyphon type of cooling system  and label  any five Components in the sketch.(b)     (i)      State  two advantages of a thermosyphon cooling system.
 (ii)      State two disadvantages of a thermosyphon cooling  system.
 |  
                        | _____________________________________________________________________________________________________ |  
                        |  |  
                        | CommentThe performance of the candidates in this  question was poor.  They could not draw  and label the components of a thermosyphon type of cooling system.  The other parts were not well attempted by  the candidates too.  The required the  answers were as follows
 (i)      Advantages  of thermo-syphon cooling system
 
                            Fewer  components.No  thermostat is needed as the engine temperature is determined by the rate of  water circulation.The  system depends on natural circulation etc.   
                            Disadvantages  of thermo-syphon cooling system -        Bulky  radiator-        Slow  in operation due to conversion current
 -        Large  quantity of water needed etc.
   |  
                        |  |  |  |  |