Few candidates were able to state  functional requirements of inspection chamber in a drainage scheme. 
                    However,  majority of the candidates were unable to: 
                    -           state the advantages of the direct  cold water supply system over the indirect cold water supply system. 
                    -           describe  the metal conduit wiring system in electrical installation works. 
                    The expected response to question 5 is  a given below: 
                    5. (a)         The functional requirements of an  inspection chamber are: 
                    
                      
                        - Means  of access for inspection and cleansing;
 
                        - Provide  access for testing the drain line;
 
                        - Materials  used for the construction must be sound and inert;
 
                        - Must  be air tight and water tight;
 
                        - The  size of the chamber must permit ready access.
 
                       
                     
                      
                    (b)       Advantages of the direct cold water  supply over the indirect cold water supply system are: 
                    
                      
                        - Few  pipes required for installation;
 
                        - Water  available at every point;
 
                        - Water  from tap is cool;
 
                        - Water  is not contaminated by dangerous elements;
 
                        - Water  pressure is good most of the time;
 
                        - No  cistern or storage tank required.
 
                       
                     
                      
                    
                      
                        - Description  of metal conduit wiring system in an electrical installation work;
 
                       
                     
                    The  metal conduit pipes are buried in floors and the electrical wires are passed  through them.  Accessories such as bends  and coupling are used to facilitate connections to fittings, appliances and  power points.  Also the metal pipes are  used as earthing conductors. 
                       |